LMP8640 Overview
The LMP8640, LMP8640-Q1 and the LMP8640HV are precision current sense amplifiers that detect small differential voltages across a sense resistor in the presence of high input mon mode voltages with a supply voltage range from 2.7 V to 12 V. The LMP8640 and LMP8640-Q1 accept input signals with mon mode voltage range from -2 V to 42 V, while the LMP8640HV accepts input signal with mon mode voltage range from -2 V to...
LMP8640 Key Features
- 1 Typical Values, TA = 25°C
- High mon-Mode Voltage Range
- LMP8640: -2 V to 42 V
- LMP8640-Q1: -2 V to 42 V, AEC-Q100
- LMP8640HV: -2 V to 76 V
- Supply Voltage Range: 2.7 V to 12 V
- Gain Options: 20 V/V; 50 V/V; 100 V/V
- Max Gain Error: 0.25%
- Low Offset Voltage: 900 µV
- Input Bias Current: 13 µA