Datasheet4U Logo Datasheet4U.com

SN65HVD101 Datasheet Io-link Phy

Manufacturer: Texas Instruments

Overview: Product Folder Order Now Technical Documents Tools & Software Support & munity SN65HVD101, SN65HVD102 SLLSE84D – MAY 2011 – REVISED MAY 2017 SN65HVD10x IO-Link PHY for Device Nodes.

General Description

The SN65HVD101 and ‘HVD102 IO-Link PHYs implement the IO-Link interface for industrial point-topoint munication.

When the device is connected to an IO-Link master through a 3-wire interface, the master can initiate munication and exchange data with the remote node while the SN65HVD10X acts as a plete physical layer for the munication.

The IO-Link driver output (CQ) can be used in pushpull, high-side, or low-side configurations using the EN and TX input pins.

Key Features

  • 1 Configurable CQ Output: Push-Pull, High-Side, or Low-Side for SIO Mode.
  • Remote Wake-Up Indicator.
  • Current Limit Indicator.
  • Power-Good Indicator.
  • Overtemperature Protection.
  • Reverse Polarity Protection.
  • Configurable Current Limits.
  • 9-V to 36-V Supply Range.
  • Tolerant to 50-V Peak Line Voltage.
  • 3.3-V/5-V Configurable Integrated LDO (SN65HVD101 ONLY).
  • 20-pin QFN Package, 4 mm × 3.5 mm 2.

SN65HVD101 Distributor