Description
The TDC7201 is designed for use with ultrasonic, laser and radar range finding equipment using timeof-flight technique.
Features
- 1 Resolution: 55 ps.
- Standard Deviation: 35 ps.
- Measurement Range:.
- Individual Mode 1: 12 ns to 2000 ns.
- Individual Mode 2: 250 ns to 8 ms.
- Combined Operation: 0.25 ns to 8 ms.
- Low Active Power Consumption: 2.7 mA.
- Supports up to 10 STOP Signals.
- Autonomous Multi-Cycle Averaging Mode for Low Power Consumption.
- Supply Voltage: 2 V to 3.6 V.
- Operating Temperature.
- 40°C to +85°C.
- SPI.