TLV2764
description
I DD
- Supply Current
- μ A
Operational Amplifier
- +
SUPPLY CURRENT vs
SUPPLY VOLTAGE
20 AV= 1
18 VIC = VDD/2 16 TA = 25° C 14 12 10
8 6 4 2 0
0 0.6 1.2 1.8 2.4 3 3.6 VDD
- Supply Voltage
- V
The TLV276x single supply operational amplifiers provide 500 k Hz bandwidth from only 20 μA while operating down to 1.8 V over the industrial temperature range. The maximum remended supply voltage is 3.6 V, which allows the devices to be operated from ("1.8 V supplies down to "0.9 V) two AA or AAA cells. The devices have been characterized at 1.8 V (end of life of 2 AA(A) cells) and at 2.4 V (nominal voltage of 2 Ni Cd/Ni MH cells). The TLV276x have rail-to-rail input and output capability which is a necessity at 1.8 V.
The low supply current is coupled with extremely low input bias currents enabling them to be used with mega-ohm resistors. Low shutdown current of only 10 n A make these devices ideal for low frequency measurement applications desiring long active battery life.
All...