TLV4062 Datasheet Text
Product Folder
Order Now
Technical Documents
Tools & Software
Support & munity
TLV4062, TLV4082
SBVS404A
- APRIL 2020
- REVISED JUNE 2020
TLV4062, TLV4082 Dual-Channel, Low-Power parator with Integrated Reference
1 Features
- 1 Wide supply voltage range: 1.5 V to 5.5 V
- Two-channel detectors in small packages
- High threshold accuracy: 1% over temperature
- Precision hysteresis: 60 mV
- Low quiescent current: 2 µA (typ)
- Temperature range:
- 40°C to +125°C
- Push-pull (TLV4062) and open-drain (TLV4082) output options
- Available in an SOT-23 and µSON package
2 Applications
- Electricity meters
- Thermostats
- Cordless power tools
- Circuit breakers
3 Description
The TLV4062 and TLV4082 are a family of highaccuracy, dual-channel parators featuring low power and small solution size. The IN1 and IN2 inputs include hysteresis to reject brief glitches, thus ensuring stable output operation without false triggering.
The TLV4062 and TLV4082 have adjustable INx inputs that can be configured by an external resistor divider pair. When the voltage at the IN1 or IN2 input goes below the falling threshold, OUT1 or OUT2 is driven low, respectively. When IN1 or IN2 rises above the rising threshold, OUT1 or OUT2 goes high, respectively.
The parators have a very low quiescent current of 2 µA (typical) and provide a precise, spaceconscious solution for low-power, voltage monitoring. The TLV4062 and TLV4082 operate from 1.5 V to 5.5 V, over the
- 40°C to +125°C temperature range....