TVS2200 Overview
The TVS2200 robustly shunts up to 40 A of IEC 61000-4-5 fault current to protect systems from high power transients or lightning strikes. The device offers a solution to the mon industrial signal line EMC requirement to survive up to ±1 kV IEC 610004-5 open circuit voltage coupled through a 42 Ω impedance. The TVS2200 uses a unique feedback mechanism to ensure precise flat clamping during a fault, assuring system...
TVS2200 Key Features
- 1 Protection Against ±1 kV, 42 Ω IEC 61000-4-5 Surge Test for Industrial Signal Lines
- Max Clamping Voltage of 28.4 V at 40 A of 8/20 µs Surge Current
- Standoff Voltage: 22 V
- Tiny 4 mm2 Footprint
- Survives Over 5,000 Repetitive Strikes of 35 A
- Robust Surge Protection
- IEC 61000-4-5 (8/20 µs): 40 A
- IEC 61643-321 (10/1000 µs): 5 A
- Low Leakage Current
- 3.5 nA Typical at 27°C