GB5101L - Battery Protection IC

Description

charge/discharge-current.

Features

  • Normal operation: 3uA typ. @ VCC = 3.9V Over-charge detection voltage (VCU) 4.25~4.3V, accuracy: ±50mV Over-charge release voltage (VCR) 4.05~4.1V, accuracy: ±50mV Over-discharge detection voltage (VDL) 2.4V, accuracy: ±100mV Over-discharge release voltage (VDR) 3.0V, accuracy: ±100mV Over-current detection voltage (VIOV) 0.15V, accuracy: ±30mV Short circuit detection voltage (VSHORT) 1.0V Reset resistance for over current protection > 500KΩ Delay time clock is generated with internal circuit A.

📥 Download Datasheet

Datasheet preview – GB5101L

Datasheet Details

Part number GB5101L
Manufacturer grenergy
File Size 722.31 KB
Description Battery Protection IC
Datasheet download datasheet GB5101L Datasheet
Additional preview pages of the GB5101L datasheet.
Other Datasheets by grenergy

Full PDF Text Transcription

Click to expand full text
Preliminary GB5101L Battery Protection IC for Single-cell Pack Features Normal operation: 3uA typ. @ VCC = 3.9V Over-charge detection voltage (VCU) 4.25~4.3V, accuracy: ±50mV Over-charge release voltage (VCR) 4.05~4.1V, accuracy: ±50mV Over-discharge detection voltage (VDL) 2.4V, accuracy: ±100mV Over-discharge release voltage (VDR) 3.0V, accuracy: ±100mV Over-current detection voltage (VIOV) 0.15V, accuracy: ±30mV Short circuit detection voltage (VSHORT) 1.