ESL16053
ESL16053 is TVS manufactured by msksemi.
description
High Temperature Storage
The specimen shall be subjected to 125 ± 2℃ for 1000 ± 12 hours in a thermostatic bath without load and then stored at room temperature and normal humidity for 1 to 2 hours. The change of varistor voltage shall be within 10 ﹪.
Temperature Cycle
The temperature cycle of specified
Step Temperature temperature shall be repeated five times and then stored at room temperature and
-40±3℃ normal humidity for one or two hours. The 2 Room Temperature change of varistor voltage shall be within 10 ﹪and mechanical damage shall be
125±3℃ examined.
4 Room Temperature
Period 30Min±3 1 hour 30Min±3 1 hour
High Temperature Load
After being continuously applied the maximum allowable voltage at 85 ± 2℃ for 1000± 2 hours, the specimen shall be stored at room temperature and normal humidity for one or two hours, the change of varistor voltage shall be within 10﹪.
Damp Heat Load/ Humidity Load
The specimen should be subjected to 40 ± 2℃, 90 to 95 ﹪RH environment, and the maximum allowable voltage applied for 1000 hours, then stored at room temperature and normal humidity for...