DESCRIPTION
Based on the TRUESENSE 5.5-micron Interline Transfer CCD Platform, the sensor features broad dynamic range, excellent imaging performance, and a flexible readout architecture that enables use of 1, 2, or 4 outputs for full resolution readout up to 64 frames per second. A vertical overflow drain structure suppresses image blooming and enables electronic shuttering for precise exposure control. Table 1. GENERAL SPECIFICATIONS Parameter Architecture Total Number of Pixels Number of Effective Pixels Number of Active Pixels Pixel Size Active Image Size Typical Value Interline CCD, Progressive Scan 2004 (H) × 1144 (V) 1960 (H) × 1120 (V) 1920 (H) × 1080 (V) 5.5 mm (H) × 5.5 mm (V) 10.56 mm (H) × 5.94 mm (V) 12.1 mm (Diagonal), 2/3″ Optical Format Aspect Ratio Number of Outputs Charge Capacity Output Sensitivity Quantum Efficiency Pan (−ABA, −PBA) R, G, B (−FBA, −QBA) R, G, B (−CBA, −PBA) 16:9 1, 2, or 4 20,000 electrons 34 mV/e− 44% 31%, 37%, 38% 29%, 37%, 39% Base ISO KAI−02150−...