MAXIMUM RATINGS
at Ta = 25°C Parameter Pump-up block supply voltage Output block supply voltage Allowable power dissipation Deflection output current Thermal resistance Operating temperature Storage temperature Symbol +B2 max +B6 max Pd max I5 max θj-c Topr Tstg Mounted on an arbitrarily large heat sink. Conditions Ratings 34 70 9 -1.5 to +1.5 3 -20 to +85 -40 to +150 Unit V V W Ap-o °C /W °C °C Stresses exceeding MAXIMUM RATINGS
may damage the device. MAXIMUM RATINGS
are stress ratings only. Functional operation above the Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect device reliability. Semiconductor Components Industries, LLC, 2013 July, 2013 D0605 MS PC B8-4579 No.7966-1/4 LA78041 Operating Conditions at Ta = 25°C Parameter Recommended supply voltage Operating supply voltage range Deflection output current Symbol +B2 +B2op I5p-p Conditions Ratings 24 16 to 33 To 2.2 Unit V V Ap-p Operating Charact...