DESCRIPTION
(See Figure 4.) The operational range of the VCTRL input is from ≤ VBB (a supply at VCC−1.42 V, maximum output amplitude) to VCC (minimum output amplitude). VBB is an externally supplied voltage equal to VCC−1.42 V (See Figures 2 and Figure 3). A variable resistor between VCC and VBB, with the wiper driving VCTRL, can control the output amplitude. Typical application circuits and a VCTRL Voltage vs. Output Amplitude graph are described in this data sheet. When left open, the VCTRL pin will be internally pulled down to VEE and operate as a standard EP16, with 100