ML524B Datasheet Preview

ML524B Datasheet

MEASURING RECEIVER

No Preview Available !

ML524B pdf
MOBILE COMMUNICATIONS MEASURING INSTRUMENTS
MEASURING RECEIVER
ML524B
25 to 1000 MHz
For Measuring Service Area
GPIB
OPTION
4
Custom-made product
The ML524B have a full range of features and functions plus de-
modulation functions for various signals. Their compact, lightweight
construction makes them suitable for a variety of measurement appli-
cations. Use of the GPIB interface option allows easy configuration
of an automatic test system controlled by a personal computer.
Features
Very compact and lightweight
High frequency stability (A synthesizer local is used. Its reference
oscillator has a high frequency stability of ±1 x 10–6.)
Wide dynamic range (80 dB without switching)
Automatic gain calibration
Direct readout of field strength
High precision level display (indication in 0.1 dB steps)
Applications
For field strength measurement
Investigation to determine service areas
Radio wave propagation test
Measurement of spurious radiation from transmitter
For other than field strength measurement
Radio monitoring
Measuring receiver
High-sensitivity signal demodulation
Specifications
RF input
Range
Display
Frequency
Resolution
Setting
Memory
Reference frequency stability
Minimum value
Voltage
measurement
(E.M.F.)
Maximum value
Setting
Accuracy (digital display)
Comparison oscillator
Minimum value
Field strength Maximum value
measurement Setting
Type of antenna
Selectivity
6 dB bandwidth
Detuning characteristics
Image ratio
Residual spurious
Detection system
Nominal impedance 50 , N-type connector
25.0000 to 999.9999 MHz
Liquid crystal display, 6 digits
Minimum digit: 1 kHz (0.5 kHz is displayed using a symbol of .)
12.5 kHz (120 kHz bandwidth), 1 kHz (15 kHz bandwidth)
Keyboard and FINE dial
Up to 100 frequencies can be stored and recalled.
±1 x 106
5 dBµV (25 to 300 MHz), 5 dBµV (300 to 999.999 MHz)
100 dBµV (25 to 999.999 MHz)
C/N: 6 dB (at minimum value), Bandwidth: 15 kHz
±2 dB (minimum value +6 dB)
Pulse generator
5 to 19 dBµV/m (25 to 300 MHz), 19 to 32 dBµV/m (300 to 999.999 MHz)
0 to 114 dBµV/m (25 to 300 MHz), 114 to 120 dBµV/m (300 to 999.999 MHz)
C/N: 6 dB (at minimum value), Bandwidth: 15 kHz
Half-wave dipole
15 ±2 kHz (15 kHz bandwidth), 120 ±20 kHz (120 kHz bandwidth)
15 kHz bandwidth 50 dB (±20 kHz off center)
60 dB (at 25.000 to 299.999 MHz), 45 dB (at 300 to 999.999 MHz)
10 dBµV (typical near 50, 130, 600, 1000 MHz)
Average value
Continued on next page
http://www.anritsu.com
295



Anritsu
Anritsu

ML524B Datasheet Preview

ML524B Datasheet

MEASURING RECEIVER

No Preview Available !

ML524B pdf
MOBILE COMMUNICATIONS MEASURING INSTRUMENTS
Measured level indication
Monitor output
IF output
Discriminator output
Output for recorder
Ambient temperature
Power
Dimensions and mass
Display: Liquid crystal display, 4 digits, Minimum digit 0.1 dB (on digital display), Up to 80 dB (on analog display)
Unit: dBµV, dBµV/m (on digital display)
AM and FM can be heard from a loudspeaker, and earphone output terminal is also provided.
Level: 85 dBµV at 80 dBµV input, Impedance: 50 (nominal), Connector: BNC-type
Level: 1 V ±20% (modulation frequency: 2 kHz, frequency deviation: 3.5 kHz, into 100 kHz load)
Impedance: 150
Connector: BNC-type
Level: 1 V ±10% (at 80 dB on digital display, into 100 kload), Impedance: 150 , Connector: 3.5ø jack
0˚ to 50˚C (operate), 20˚ to 60˚C (storage)
12 Vdc: <1 A
100 Vac, 50/60 Hz, 35 VA (using MZ114A AC Power Pack supplied)
Ni-Cd battery (optional MZ110B Battery Pack)
210 (W) x 60 (H) x 175 (D) mm, 4 kg
Power supply selection guide
Type of power supply
Model
MZ137A Battery Pack
Dry cell
Ni-Cd battery
MZ110B Battery Pack
AC supply
MZ114A AC Power Pack
When used with ML524B
Operates continuously for about 2.5 to
5 hours1
Sold separately
Remarks
Twelve alkaline dry cells (LR20)
Does not permit GPIB operation
Operates continuously for about 30 to
60 minutes1
Sold separately
Six Ni-Cd batteries with the same dimensions
as R14 battery, chargeable 200 to 300 times
Fits inside the receiver
Does not permit GPIB operation
Permits operation at 100/220 Vac
One of accessories supplied
DC power is fed to the EXT +12 V terminal
of the receiver.
Permits GPIB operation
EMC, safety
External DC supply
The receiver can be operated directly
from an external 12 Vdc supply.
One DC power cord is supplied.
Permits GPIB operation
Battery charger
MZ115B Battery Charger
Sold separately
Two MZ110B can be charged simultaneously.
EMC, safety
1: For continuous reception after power on, with calibration performed once only (more calibrations reduce the operating time). Operating is also affected by how
the battery has been stored, and operating temperature.
Ordering information
Please specify model/order number, name, and quantity when ordering.
Model/Order No.
Name
ML524B
Main frame
Measuring Receiver
J0231
J0144
A0002
MZ114A
B0259
W0285AE
Standard accessories
Connecting cord for recorder
(3.5ø plug · – · alligator clips), 1.5 m:
DC power cord
(RM12BPG-5S · 2CC7 · arrow tips), 1.5 m:
Earphone:
AC Power Pack:
Carrying case:
ML524A/B/C operation manual:
1 pc
1 pc
1 pc
1 pc
1 pc
1 copy
ML524B-01
ML524B-05
Options
GPIB
Terminated voltage indication
Model/Order No.
Name
MP612A
MP613A
A0004
MZ110B
MZ115B
MZ114A
MP635A
MZ137A
MB19A
J0006
J0007
J0008
J0009
MP663A
MP651B
MP18A
MB9A
MP520B
MP520D
Optional accessories
RF Fuse Holder
RF Fuse Element (5 pcs/set)
Headphone
Battery Pack (with six Ni-Cd batteries)
Battery Charger
AC Power Pack
Log-periodic Antenna
Battery Pack
Tripod (for MP635A)
GPIB cable, 0.5 m
GPIB cable, 1 m
GPIB cable, 2 m
GPIB cable, 4 m
Dipole Antenna (with pole and tripod)
Dipole Antenna
Pole (for MP651B)
Tripod (for MP651B)
CM Directional Coupler
(25 to 1000 MHz, 75 , NC-type connector)
CM Directional Coupler
(100 to 1700 MHz, 50 , N-type connector)
296 For product ordering information, see pages 3 – 6


Part Number ML524B
Description MEASURING RECEIVER
Maker Anritsu
Total Page 2 Pages
PDF Download
ML524B pdf
Download PDF File
ML524B pdf
View for Mobile






Related Datasheet

1 ML524B MEASURING RECEIVER Anritsu
Anritsu
ML524B pdf




Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

site map

webmaste! click here

contact us

Buy Components