Pilot Operated Directional Valves

No Preview Available !

DSHG-10 pdf
www.DataSheet4U.com
Pub. EC-0404
SOLENOID CONTROLLED PILOT
OPERATED DIRECTIONAL VALVES
DSHG-01/03/04/06/10
PILOT OPERATED DIRECTIONAL VALVES
DHG/04/06/10
DIRECTIONAL
MANUALLY OPERATED
CONTROLS
DIRECTIONAL VALVES
DMG-01/03/04/06/10
DMT-03/06/10
General Information
Up to 31.5 MPa (4570 PSI), 1100L/min (291 U.S.GPM)
Solenoid contorolled Pilot Operated Valves ............................ Page 4
Thease valves are composed of a solenoid operated pilot valve and a pilot
operated slave valve. When a solenoid is energised the pilot valve directs the
flow to move the spool of the slave valve, thus changing the direction of flow
in the hydraulic circuit.
High Pressure High Flow
In these valves, the nominal size "04" can provide 300 L/min (79.3 U.S.GPM),
"06" can provide 500 L/min (132 U.S.GPM) and "10" can provide 1100 L/min
(291 U.S.GPM) in the maximum flow respectivelyand theycan alsowithstand
such a high pressure as 31.5 Mpa {4570 PSI} as the maximum operating
pressure. With these features of high pressure and high flow, the valves can
make the size or configuration of the equipment compact.
E
Low Pressure Drop
As the pressure drop of each size of the valve becomes minimal, the more of
energy saving of the equipment is possible.
Easy Change of Pilot and Drain System
The change of the pilot from external to internal and the change of the drain
from internal to external or viceversa can be done easily by putting on or
removing the relevant plug on the valve.
Pilot Operated Directional Valves
............................ Page
34
These valves perform a change over of spool by
hydraulic pilot and shift the direction of oil flow.
XPY
Manually Operated Directional Valves
............................ Page
40
These valves may be used to manually shift the spool
position and change the direction of oil flow.
No.1



Yuken
Yuken

DSHG-10 Datasheet Preview

DSHG-10 Datasheet

Pilot Operated Directional Valves

No Preview Available !

DSHG-10 pdf
www.DataSheet4U.com
Solenoid Controlled
Pilot Operated Directional Valves
Pilot Operated Directional Valves
Manually Operated Directional Valves
Solenoids / Mounting
DIRECTIONAL
CONTROLS
Solenoids
(Only for Solenoid Controlled Pilot Operated Directional Valves)
Solenoid connectors (DIN Connector)
The solenoid connectors are conform to the international standard ISO 4400 (Fluid power systems and components-
Three-pin electrical plug connectors-Characteristics and requirements).
AC Solenoids
50-60 Hz common service solenoids do not require rewiring when the applied frequency is changed.
DC Solenoids (Reputable K-Series)
These DC solenoids have surge absorbers for K-series functions. The three advantages of them are as mentioned
below:-
1. Since surge voltage can be controlled to a very low figure, electric control devices, such as a computer, can be used
without any interference like noise.
2. There being no spark between contacts, the life of the relay becomes longer.
3. Time lag for spool return after de-energisation of the solenoid is very short.
R Type Solenoids
These are rectifier and surge absorber incorporated direct current solenoids which can be used by connecting directly
to the AC power source. They have, like other DC solenoids, such advantages that the sound in on-off operation is
quite low and the coils are hardly burnt out even if the spool is stuck at the half way of its changeover for contaminant
parti-cles etc. Moreover, theycan be used almost permanentlywithout being affected bya surgevoltagefrom theoutside.
Thus, they are the solenoids of high reliability and durability.
Insulation Class of Solenoid
Class H
Mounting
Mounting surface dimensions confrom to ISO 4401, Hydraulic fluild power-Four-port directional control valves-
Mounting surfaces.
Model Numbers
DSHG-01
DMG-01
DMG-03
DSHG-03
(S)-DSHG-04
DHG-04
DMG-04
ISO Code of Mounting Surface
ISO 4401-AB-03-4-A
ISO 4401-AC-05-4-A
ISO 4401-AC-05-4-A
ISO 4401-AD-07-4-A
(S)-DSHG-06
DHG-06
DMG-06
ISO 4401-AE-08-4-A
(S)-DSHG-10
DHG-10
DMG-10
ISO 4401-AF-10-4-A
The main ports conform to ISO 4401-AC-05-4-A. The pilot and
drain ports conform to the ISO.
No.2


Part Number DSHG-10
Description Pilot Operated Directional Valves
Maker Yuken
Total Page 30 Pages
PDF Download
DSHG-10 pdf
Download PDF File
DSHG-10 pdf
View for Mobile






Related Datasheet

1 DSHG-10 Pilot Operated Directional Valves Yuken
Yuken
DSHG-10 pdf




Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

site map

webmaste! click here

contact us

Buy Components