IVA-05228 is Silicon Bipolar MMIC 1.5 GHz Variable Gain Amplifier Differential Option manufactured by Agilent(Hewlett-Packard).
- Part of the IVA-05228_Agilent(Hewlett comparator family.
- Part of the IVA-05228_Agilent(Hewlett comparator family.
Features
- Differential Input and Output Capability
- DC to 1.5 GHz Bandwidth; 2.0 Gb/s Data Rates
- High Gain: 30 d B Typical
- Wide Gain Control Range: 30␣ d B Typical
- 5 V Bias
- 5 V Vgc Control Voltage, Igc␣ <␣ 3m A
- Fast Gain Control Response: < 10 ns Typical
- Hermetic Ceramic Package
Description
The IVA-05228 is a variable gain amplifier housed in a miniature ceramic hermetic surface mount package. This device can be used in any bination of singleended or differential inputs or outputs (see Functional Block Diagram). The lowest frequency of operation is limited only by the values of user selected blocking and bypass capacitors. Typical applications include variable gain amplification for fiber optic systems (e.g., SONET) with data rates up to 2.0 Gb/s, mobile radio and satellite receivers, millimeter wave receiver IF amplifiers and munication receivers. The IVA series of variable gain amplifiers is fabricated using HP’s 10 GHz f T, 25 GHz f MAX
28 Package
PIN 1
Applications
- LNA or Gain Stage for 2.4␣ GHz and 5.7 GHz ISM Bands
- Front End Amplifier for GPS Receivers
- LNA or Gain Stage for PCN and MMDS Applications
- C-Band Satellite Receivers
- Broadband Amplifier for Instrumentation
ISOSAT™-I silicon bipolar process. This process uses nitride self-alignment, submicrometer lithography, trench isolation, ion implantation, gold metallization and polyimide inter-metal dielectric and scratch protection to achieve excellent performance, uniformity and reliability.
6-181
5965-9683E
Absolute Maximum Ratings
Symbol VCC-Vee Parameter Device Voltage Power Dissipation[2,3] Input Power Vgc-Vee TJ TSTG Junction Temperature Storage Temperature Units V m W d Bm V °C °C Absolute Maximum[1] 8 600 +14 7 200 -65 to 200 Thermal Resistance: θjc = 50°C/W
[2,4]