ACHS-7193 - Hall-Effect Based Linear Current Sensor

This page provides the datasheet information for the ACHS-7193, a member of the ACHS Hall-Effect Based Linear Current Sensor family.

Datasheet Summary

Description

The Broadcom® ACHS-719x (±10A to ±50A) fully integrated Hall-effect based isolated linear current sensors are designed for AC or DC current sensing in industrial, commercial, and communications systems.

Features

  • Wide operating temperature:.
  • 40ºC to +110ºC.
  • Internal conductor resistance: 0.7 mΩ typ.
  • Sensing current range: ± 10A ~ ± 50A.
  • Output sensitivity: 40 mV/A to 185 mV/A.
  • Output voltage proportional to AC or DC currents.
  • Ratiometric output from supply voltage.
  • Single supply operation: 5.0V.
  • Low-noise analog signal path.
  • Device bandwidth is set via the new FILTER pin.
  • 80 kHz typ. bandwidth with 1-nF filter capacitor.
  • Factory-trimmed.

📥 Download Datasheet

Datasheet preview – ACHS-7193

Datasheet Details

Part number ACHS-7193
Manufacturer Broadcom
File Size 0.98 MB
Description Hall-Effect Based Linear Current Sensor
Datasheet download datasheet ACHS-7193 Datasheet
Additional preview pages of the ACHS-7193 datasheet.
Other Datasheets by Broadcom

Full PDF Text Transcription

Click to expand full text
ACHS-719x Fully Integrated, Hall-Effect Based Linear Current Sensor IC with 3 kVRMS Isolation and a Low-Resistance Current Conductor Data Sheet Description The Broadcom® ACHS-719x (±10A to ±50A) fully integrated Hall-effect based isolated linear current sensors are designed for AC or DC current sensing in industrial, commercial, and communications systems. Inside each ACHS-719x IC is a precise, low-offset, linear Hall circuit with a copper conduction path located near the surface of the die. Applied current flowing through this copper conduction path generates a magnetic field that the differential Hall sensors convert into a proportional voltage. Device accuracy is optimized across the operating ambient temperature through the close proximity of the magnetic signal to the Hall sensors.
Published: |