900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Crydom

10PCVxxx Datasheet Preview

10PCVxxx Datasheet

Analog Input Power Controller

No Preview Available !

Series PCV
Analog Input Power Controller
Operates at 60Hz & 50Hz
Internal Snubber
Industry Standard Package
Control Circuit Requires No
Adjustment or Calibration
The PCV Series proportional controllers
are self contained power control mod-
ules integrating a complete phase fired
logic control system and a solid state
relay in the same standard package.
Typical applications include heaters,
vibratory feeders and tungsten lamps.
MODEL NUMBERS
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current Range [Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (1 Cycle) [Apk]
Max. Off-State Leakage Current @ Rated Voltage [mA]
Maximum I 2 t for Fusing (8.3 msec) [A 2sec]
Maximum Voltage Drop (100% On) [Vpk]
Minimum Off-State dv/dt [V/µsec]
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS
Control Voltage Range
Typical Input Current @ 5 Vdc
GENERAL NOTES
All parameters at 25º C unless otherwise specified.
7PCV2415 7PCV2425
10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490
100-240 100-240 100-240 100-240 100-240
.15-15
.15-25
.15-50
.15-75
.15-90
600 600 600 600 600
150
250
625
1000
1200
10 15 20 20 20
94
260
1620
4150
6000
1.6 1.6 1.6 1.6 1.6
200 200 200 200 200
0.5 0.5 0.5 0.5 0.5
www.DataSheet4U.com
7PCV24xx
2-7 Vdc
10PCV24xx
2-10 Vdc
4 mA
4 mA
© 2002 CRYDOM CORP, Specifications subject to change without notice.
TYPICAL APPLICATIONS
Industrial Temperature Controllers
Light Dimming
Vibratory Feeders
Resistive Heating Elements
Conveyor Speed Control
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications
including, but not limited to the following:
AC Motor Control
Three Phase Motors
Transformers requiring pure sine wave input
Zero Crossing Applications
Please contact Crydoms application
engineering department for additional
information and specific application
questions.
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 1 OF 2
Percentage On vs. Input Voltage
100
80
60
40
50 Hz
20 60 Hz
0
2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5
Input Voltage
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506




Crydom

10PCVxxx Datasheet Preview

10PCVxxx Datasheet

Analog Input Power Controller

No Preview Available !

WIRING DIAGRAM
~
1 OUTPUT 2
PROPORTIONAL
CONTROLLER
43
INPUT
-- +
CURRENT DERATING CURVES
50A
60
1˚C/W .5˚C/W
90
1.5˚C/W
40 100
2˚C/W
20 110
NO HEATSINK
120
0
10 20 30 40 50 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [˚C]
Series PCV
Analog Input Power Controller
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
Dielectric Strength, Signal to Base
Ambient Operating Temperature Range
Ambient Storage Temperature Range
2500 Vrms
2500 Vrms
-30 to 80˚C
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.5 oz. (100g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1.10
(27.9)
.45
(11.4)
8-32 TERMINAL
(2 PLACES )
1.87
(47.5)
1 OUTPUT 2
SOLID-STATE RELAY
-- +
4 INPUT 3
2.30
(58.4)
1.70
(43.2)
All dimensions are in inches (millimeters)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
BASE PLATE
.125 (3.2)
1.00
(25.4)
1.80
(45.7)
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
15A
15
2˚C/W 112
4˚C/W
10
6˚C/W
116
5
NO HEATSINK
120
124
0
3 6 9 12 15 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [˚C]
75A
90
95
.5˚C/W .3˚C/W
60 100
1˚C/W
110
30
120
0
15 30 45 60 75 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [˚C]
25A
30 95
1˚C/W
25 100
3˚C/W 2˚C/W
20
15 110
10
NO HEATSINK
5 120
0
5 10 15 20 25 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [˚C]
90A
120 90
.5˚C/W
.2˚C/W
.4˚C/W 100
80
1˚C/W
110
40
120
0
20 40 60 80 0 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [˚C]
©2002 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506


Part Number 10PCVxxx
Description Analog Input Power Controller
Maker Crydom
Total Page 2 Pages
PDF Download

10PCVxxx Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 10PCVxxx Analog Input Power Controller
Crydom





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy