Click to expand full text
3.3V & 5V VCXO - Complementary PECL
2011/65/EU
Specifications GVXO-34L: +3.3V supply GVXO-34S: +5.0V supply
GVXO-34
14.00 (max)
9.80 (max)
1.00
5.08 123 654
1.20
6.00 (max)
PAD CONNECTION
1 Control voltage
2
Enable / disable or Not connected
3 Ground
4 Output 1
5 Output 2
6 Supply
6 5 4 3.00
5.80 6.20
1 2 3 3.00 1.60 1.60
3.48 TOP VIEW
Features
Complementary LV-PECL or PECL outputs Fast rise / fall times Popular telecomms package layout Enable / disable tristate function
Enable / Disable Function
Input (pad 2)*
Open ‘1’ level VIH ‘0’ level VIL
Output 1 (pad 4)
Active High (‘1’)
Active
Output 2 (pad 5)
Active Low (‘0’)
Active
* Note: GVXO-34L: ‘0’ level = VIL ≤ +1.7V, ‘1’ level = VIH ≥ +2.2V GVXO-34S: ‘0’ level = VIL ≤ +3.40V, ‘1’ level = VIH ≥ +3.