900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Hy-Line

P15C24S05 Datasheet Preview

P15C24S05 Datasheet

15W DC-DC Converter

No Preview Available !

15W DC-DC Converter P15C-Series
Output voltage up to 140V
4:1 wide input voltage range
Six-Sided continuous shield
High efficiency up to 86%
Standard 2" x 1.6" x 0.4" package
Fixed switching frequency
Model selection guide
Typ Input nominal Input current
voltage
full-load
[VDC]
Single output
[mA]
P15C24S05
9 ... 36
822
P15C24S12
9 ... 36
801
P15C24S15
9 ... 36
801
P15C48S05 18 ... 75
411
P15C48S12 18 ... 75
401
P15C48S15 18 ... 75
401
P15C48S110 20 ... 72
382
P15C48S140 20 ... 72
373
Dual output
P15C24D05
9 ... 36
822
P15C24D12
9 ... 36
801
P15C24D15
9 ... 36
801
P15C48D05 18 ... 75
411
P15C48D12 18 ... 75
401
P15C48D15 18 ... 75
401
Output
voltage
[VDC]
5
12
15
5
12
15
110
140
http://www.DataSheet4U.net/
±5
±12
±15
±5
±12
±15
Output
current
[mA]
3000
1250
1000
3000
1250
1000
140
110
±1500
±625
±500
±1500
±625
±500
Efficiency
typ.
[%]
79
82
82
80
82
82
84
86
80
82
82
80
82
82
Capacitor
load max.
[uF]
6800
890
570
6800
890
570
-
-
2 x 1700
2 x 300
2 x 200
2 x 1700
2 x 300
2 x 200
Circuit diagram
+ INPUT
Remote ON
Remote OFF
- INPUT
The output voltage can be
externally trimmed by using the
method shown below.
( ) for dual output trim
1
6 (5)
+ OUTPUT
4 DC/DC - Converter 8 (8)
R - Trim down
P15Cxxxxx
CL
2 7(7)
R - Trim up
- OUTPUT
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: power@hy-line.de
Schweiz:
Gründenstraße 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: power@hy-line.ch
datasheet pdf - http://www.DataSheet4U.net/




Hy-Line

P15C24S05 Datasheet Preview

P15C24S05 Datasheet

15W DC-DC Converter

No Preview Available !

15W DC-DC Converter P15C-Series
Specifications
Input
Voltage range
Filter
Input surge voltage for
100mS max.
Remote CTRL
Remote CTRL input current
Remote CTRL input reference
Output
Power
Voltage accuracy
Trim adjustment range
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Line voltage regulation
Load voltage regulation 10%
to full load
Transient response recovery time
Temperature coefficient
Minimum load
24V type : 9 ... 36 VDC
48V type : 18 … 75 VDC
HV type : 20 … 72 VDC
π Pi type
24V type : 50 VDC max.
48V type : 100 VDC max.
On: open or 3.5..12 VDC
Off : 0...1.2 VDC
-2.5mA
-Input
15W max
± 2%
±10 %
5, 12, 15 V type: 75 mVp-p
110 V type: 100mVp-p
140 V type: 250mVp-p
Hiccup, automatics recovery
± 0.5%
single: ± 1%
dual: ± 5%
110 V,140 V type: ± 1%
500 µs at 25 % load chance
± 0.02% / °C
10 % to maintain the
specified regulation
General
Efficiency
Switching frequency
Isolation voltage
Isolation Resistance
Isolation Capacitance
MTBF
Standard in accordance with
Environmental
Operating temperature
Storage temperature
Maximum case temp.
Thermal impedance
Thermal shock
Vibration
Humidity
Cooling
Physical
Dimensions
Weight
Case material
Potting material
Conducted & radiated emissions
See table
300 kHz, typ.
1600 VDC
109 min.
300 pF, max.
2x106 hrs
EN60950, IEC60950, UL1950
-40 °C to +85 °C
(with derating)
-55 °C to +105 °C
+100 °C
10°C/W
8.24 °C/W with heat-sink 7G-0011A
MIL-STD-810D
2G, 10-55 Hz, 30 min., XYZ-axis
5% to 95% RH
Free-air convection
2 x 1.6 x 0.4 inches
50.8 x 40.6 x 10.4 mm
48 g
Nickel-coated copper
Epoxy (UL94-V0)
EN55022 Level A
Dimensions
Derating
http://www.DataSheet4U.net/
All dimensions in inches (mm)
Pin Pitch tolerance ±0.014 (0.35)
Pin connections
Pin Single
1 + Input
2 - Input
4 CTRL
5 No pin
6 + Output
7 - Output
8 Trim
Dual
+ Input
- Input
CTRL
+ Output
Common
- Output
Trim
Life Support Policy: HY-LINE does not authorize the use of
any of its products for use in life support devices or systems
without the express written approval of an officer of the
Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used
in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in significant
injury to the user.
Rev: 04 / 2005 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: power@hy-line.de
Schweiz:
Gründenstraße 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: power@hy-line.ch
datasheet pdf - http://www.DataSheet4U.net/


Part Number P15C24S05
Description 15W DC-DC Converter
Maker Hy-Line
PDF Download

P15C24S05 Datasheet PDF






Similar Datasheet

1 P15C24S05 15W DC-DC Converter
Hy-Line





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components