Parameter
Blocking Voltage
Load Current
On-Resistance (max)
Rating
250
200
15
Units
VP
mArms / mADC
Features
Integrated active current-limit protection
Thermal shutdown
Linear AC or DC operation
Low power consumption
Clean, bounce-free switching
High surge capability
Low power drive requirements
Surface mount version available
Tape & reel packaging available
Applications
Fault protected switch
Instrumentation
Elevator controls
Industrial controls
Security
Peripherals
Automatic tuning/balancing
Transducer driver
Pre-driver for large electro-mechanical relays
Telecom switching
Medical equipment
Pin Configuration
AC/DC Configuration
1
+ Control
2
– Control
3
Do Not Use
6
Load
5
Do Not Use
4
Load
DC Only Configuration
1
6
+ Control
2
5
– Control
3
4
Do Not Use
+ Load
– Load
CPC1510
Single-Pole, Normally Open Relay
with Integrated Current Limit
Description
The CPC1510 is a single-pole, normally
open (1-Form-A) Solid State Relay with an
integrated current limit feature that can replace
electromechanical relays while enhancing the
robustness of wireline-interface applications.
The relay is constructed using a GaAIAs LED for
actuation control and an integrated monolithic die for
the switch output. The die, fabricated in a
high-voltage dielectrically isolated technology,
comprises a photodiode array, switch control with
active current limiting circuitry, and MOSFET
switches. The active current limit circuitry in the
CPC1510 also provides a thermal shutdown feature
offering excellent power cross immunity for improved
survivability in harsh environments.
These enhancements greatly improve the robustness
of end systems using this device compared to
systems using relays without the integrated current
limit. In addition, the active current limit circuitry
enables the CPC1510 to pass FCC 68.302 and
other regulatory voltage surge requirements when
adequate overvoltage protection is provided. The
CPC1510 relay may be used in both unidirectional
DC applications as well as bi-directional AC
applications.
Approvals
UL Approved Component: File # E76270
CSA Certified Component: Certificate # 1172007
EN/IEC 60950-1 Certified Component: Pending
Ordering Information
Part #
CPC1510G
CPC1510GS
CPC1510GSTR
Description
6-Pin 0.250" Wide, Through Hole (50/Tube)
6-Pin 0.250" Wide, Surface Mount (50/Tube)
6-Pin 0.250" Wide, Surface Mount (1000/Reel)
Switching Characteristics of
Normally Open Devices
Form-A
IF
I
LOAD
90%
ton
10%
toff
DS-CPC1510-R04
www.ixysic.com
1




IXYS

CPC1510GSTR Datasheet Preview

CPC1510GSTR Datasheet

Normally Open Relay

No Preview Available !

INTEGRATED CIRCUITS DIVISION
CPC1510
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Ratings
250
5
Units
VP
V
Input LED Current
Continuous
50
mA
Peak (10ms)
Input Control Current
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
10
150
800
3750
-40 to +85
-40 to +125
A
mA
mW
mW
Vrms
°C
°C
1 Derate Linearly 1.33 mW/ºC
2 Derate Linearly 1.67 mW/ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
Recommended Operating Conditions
Parameter
Load Current, Continuous
Symbol Configuration Min Nominal Max
AC/DC
-
IL
DC-Only
-
-
200
-
350
Input Control Current
Operating Temperature Range
IF
-
3
5
10
TA
-
-40
-
+85
Units
mArms / mADC
mADC
mA
ºC
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Conditions
Symbol Min
Typ
Max
Units
Current Limit
AC/DC Configuration
DC Configuration
300
366
IF=5mA, VL=±5V, t=5ms
ILMT
600
730
450
920
mAP
On-Resistance
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
IF=5mA, IL=100mA
VL=200V
6
13
15
RON
1.5
3.3
3.75
ILEAK
-
1.3e-5
1
µA
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
IF=5mA, IL=10mA, VL=10V
ton
toff
0.845
-
0.26
2
ms
IF=0mA, VL=1V, f=1MHz
IF=0mA, VL=50V, f=1MHz
CO
-
205
65
-
pF
Input Control Current to Activate
Input Control Current to Deactivate
LED Forward Voltage
Common Characteristics
IL=100mA
IL=100mA
IF=5mA
IF
-
-
2
mA
IF
0.2
-
-
mA
VF
1.15
1.37
1.5
V
Input to Output Capacitance
-
CI/O
-
3
-
pF
2
www.ixysic.com
R04


Part Number CPC1510GSTR
Description Normally Open Relay
Maker IXYS
PDF Download

CPC1510GSTR Datasheet PDF






Similar Datasheet

1 CPC1510GSTR Normally Open Relay
IXYS





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy