Current Transducer LTSR 6-NP For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).

IPN = 6 At 16073 Electrical data IPN IPM ÎP VOUT VREF G NS RL C Lmaxi R IM TCR IM VC IC X Primary nominal current rms Primary current, measuring range Overload capability Output voltage (Analog) @ IP IP = 0 Reference voltage (internal reference), refout mode Reference voltage (external reference), refin mode Sensitivity Number of secondary turns (± 0.1 %) Load resistance Maximun capacitive loading Internal measuring resistance (± 0.5 %) Temperature coefficient of R IM Supply voltage (± 5 %) Current consumption @ VC = 5 V Typ Accuracy @ IPN , TA = 25°C Accuracy with R IM @ IPN , TA = 25°C Linearity error 6 0 ..

± 19.

Key Features

  • Closed loop (compensated) multi.
  • range current transducer using the Hall effect Unipolar voltage supply Isolated plastic case recognized according to UL 94-V0 Compact design for PCB mounting Incorporated measuring resistance Extended measuring range Access to the internal voltage reference Possibility to feed the transducer reference from external supply. www. DataSheet4U. com 250 At 2.5 ± (0.625.
  • IP/IPN) V 2.5 2) V.