900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






MacMic

MM30FU120K Datasheet Preview

MM30FU120K Datasheet

FRED

No Preview Available !

May 2015
Version 01
MM30FU120K
1200V 30A FRED
RoHS Compliant
PRODUCT FEATURES
APPLICATIONS
Ultrafast Recovery Time
Freewheeling, Snubber, Clamp
Low Recovery Loss
Inversion Welder
Soft Reverse Recovery Characteristics PFC
Low Leakage Current
Low Forward Voltage
High Surge Current Capability
Plating Power Supply
Ultrasonic Cleaner and Welder
1
2
Converter & Chopper
DESCRIPTION
UPS
FRED from MacMic utilizes advanced processing techniques to achieve
ultrafast recovery times and higher forward current. Its soft recovery
characteristics and high reliability suit for wide industrial applications.
TO-220
ABSOLUTE MAXIMUM RATINGS
T C =25°C unless otherwise specified
Symbol
Parameter/Test Conditions
Values
VR
VRRM
Maximum D.C. Reverse Voltage
Maximum Repetitive Reverse Voltage
1200
IF(AV)
Average Forward Current
TC=80
30
IF(RMS)
RMS Forward Current
TC=80
42
IFSM
Non Repetitive Surge Forward Current TJ=25,t=10ms, 50Hz, Sine
250
PD
Power Dissipation
156
TJ
Junction Temperature
-55 to +150
TSTG
Storage Temperature Range
-55 to +125
Torque To Heat Sink
RecommendedM3
1.1
RthJC
Junction to Case Thermal Resistance
0.8
Weight
2.5
Unit
V
A
W
Nm
/W
g
ELECTRICAL CHARACTERISTICS
T C =25°C unless otherwise specified
Symbol
Parameter/Test Conditions
Min. Typ. Max. Unit
IRM
Maximum Reverse Leakage Current
VR =1200V
VR =1200V, TJ = 125
10 μA
1 mA
VF
Forward Voltage
IF=30A
IF=30A,TJ=125
trr
Reverse Recovery Time (IF = 1A, dIF/dt = -200A/μs, VR = 30V)
2.8
3.3
V
2.3
25
30 ns
trr
Reverse Recovery Time (IF = 0.5A, IR=1A, IRR = 0.25A)
40
45 ns
trr
Reverse Recovery Time
IF =30A,VR =600V,
80
ns
IRRM
Maximum Reverse Recovery Current
dIF/dt = -200A/μs
5
A
trr
Reverse Recovery Time
IF = 30A,VR =600V,
280
ns
IRRM
Maximum Reverse Recovery Current
dIF/dt = -200A/μs ,TJ=125
10
A
MacMic Science & Technology Co., Ltd.
1
Add#18, Hua Shan Zhong Lu, New District, Changzhou City, Jia ngsu Province, P. R .of China
Tel.+86-519-85163708 Fax+86-519-85162291 Post Code213022 Websitewww.macmicst.com




MacMic

MM30FU120K Datasheet Preview

MM30FU120K Datasheet

FRED

No Preview Available !

MM30FU120K
60
25
50
125
40
30
20
10
0
0
1
2
3
4
VF(V)
Figure 1. Forward Voltage Drop vs Forward Current
20
25
125
15
10
5
0
100 200 300 400 500
dIF/dt(A/μs)
Figure 3. Reverse Recovery Current vs dIF/dt
40
30
DC
20
10
0
25 50 75 100 125 150 175
TC()
Figure 5.Forward current vs Case temperature
600
25
500
125
400
300
200
100
0
100 200 300 400 500
dIF/dt(A/μs)
Figure 2. Reverse Recovery Time vs dIF/dt
3
25
2.5
125
2
1.5
1
0.5
0
100 200 300 400 500
dIF/dt(A/μs)
Figure 4. Reverse Recovery Charge vs dIF/dt
10
1
0.1
0.01
0.001 0.01 0.1
1
10
Rectangular Pulse Duration (s)
Figure 6.Transient Thermal Impedance
2


Part Number MM30FU120K
Description FRED
Maker MacMic
PDF Download

MM30FU120K Datasheet PDF






Similar Datasheet

1 MM30FU120B FRED
MacMic
2 MM30FU120K FRED
MacMic





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy