900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf




  ON Semiconductor Electronic Components Datasheet  

NCP360 Datasheet

USB Positive Overvoltage Protection Controller

No Preview Available !

NCP360, NCV360
USB Positive Overvoltage
Protection Controller with
Internal PMOS FET and
Status FLAG
The NCP360 disconnects systems at its output when wrong VBUS
operating conditions are detected at its input. The system is positive
overvoltage protected up to +20 V.
Thanks to an integrated PMOS FET, no external device is
necessary, reducing the system cost and the PCB area of the
application board.
The NCP360 is able to instantaneously disconnect the output from
the input if the input voltage exceeds the overvoltage threshold
(OVLO).
The NCP360 provides a negative going flag (FLAG) output, which
alerts the system that a fault has occurred.
In addition, the device has ESDprotected input (15 kV Air) when
bypassed with a 1 mF or larger capacitor.
Features
Very Fast Protection, Up to 20 V, with 25 mA Current Consumption
Onchip PMOS Transistor
Overvoltage Lockout (OVLO)
Undervoltage Lockout (UVLO)
Alert FLAG Output
EN Enable Pin
Thermal Shutdown
Compliance to IEC6100042 (Level 4)
8 kV (Contact)
15 kV (Air)
ESD Ratings: Machine Model = B
ESD Ratings: Human Body Model = 2
6 Lead UDFN 2x2 mm Package
5 Lead TSOP 3x3 mm Package
NCV Prefix for Automotive and Other Applications Requiring
Unique Site and Control Change Requirements; AECQ100
Qualified and PPAP Capable
These are PbFree Devices
Applications
USB Devices
Mobile Phones
Peripheral
Personal Digital Applications
MP3 Players
http://onsemi.com
MARKING
DIAGRAMS
UDFN6
MU SUFFIX
CASE 517AB
1
xx M
G
M = Date Code
G = PbFree Package
5
1
TSOP5
SN SUFFIX
CASE 483
xxxAYWG
G
1
A = Assembly Location
Y = Year
W = Work Week
G = PbFree Package
(Note: Microdot may be in either location)
ORDERING INFORMATION
See detailed ordering, marking and shipping information in the
package dimensions section on page 11 of this data sheet.
© Semiconductor Components Industries, LLC, 2012
March, 2012 Rev. 10
1
Q
Publication Order Number:
NCP360/D


  ON Semiconductor Electronic Components Datasheet  

NCP360 Datasheet

USB Positive Overvoltage Protection Controller

No Preview Available !

NCP360, NCV360
PIN CONNECTIONS
EN 1
6 FLAG
GND 2 PAD1 5 OUT
IN 3
UDFN6
4 OUT
(Top Views)
IN 1
5 OUT
GND 2
EN 3
4 FLAG
TSOP5
PIN FUNCTION DESCRIPTION (UDFN6 Package)
Pin No. Name
Type
Description
1 EN INPUT Enable Pin. The device enters in shutdown mode when this pin is tied to a high level. In this case the
output is disconnected from the input. To allow normal functionality, the EN pin shall be connected to
GND or to a I/O pin. This pin does not have an impact on the fault detection.
2 GND POWER Ground
3 IN POWER Input Voltage Pin. This pin is connected to the VBUS. A 1 mF low ESR ceramic capacitor, or larger,
must be connected between this pin and GND.
4, 5 OUT OUTPUT Output Voltage Pin. The output is disconnected from the VBUS power supply when the input voltage is
above OVLO threshold or below UVLO threshold. A 1 mF capacitor must be connected to these pins.
The two OUT pins must be hardwired to common supply.
6 FLAG OUTPUT Fault Indication Pin. This pin allows an external system to detect a fault on VBUS pin. The FLAG pin
goes low when input voltage exceeds OVLO threshold. Since the FLAG pin is open drain functionality,
an external pull up resistor to VCC must be added.
PAD1 POWER Exposed Pad. Can be connected to GND or isolated plane. Must be used to thermal dissipation.
PIN FUNCTION DESCRIPTION (TSOP5 Package)
Pin No. Name
Type
Description
1 IN POWER Input Voltage Pin. This pin is connected to the VBUS. A 1 mF low ESR ceramic capacitor, or larger,
must be connected between this pin and GND.
2 GND POWER Ground
3 EN INPUT Enable Pin. The device enters in shutdown mode when this pin is tied to a high level. In this case the
output is disconnected from the input. To allow normal functionality, the EN pin shall be connected to
GND or to a I/O pin. This pin does not have an impact on the fault detection.
4 FLAG OUTPUT Fault Indication Pin. This pin allows an external system to detect a fault on VBUS pin. The FLAG pin
goes low when input voltage exceeds OVLO threshold. Since the FLAG pin is open drain functionality,
an external pull up resistor to VCC must be added.
5 OUT OUTPUT Output Voltage Pin. The output is disconnected from the VBUS power supply when the input voltage is
above OVLO threshold or below UVLO threshold. A 1 mF capacitor must be connected to this pin.
http://onsemi.com
2


Part Number NCP360
Description USB Positive Overvoltage Protection Controller
Maker ON Semiconductor
PDF Download

NCP360 Datasheet PDF





Similar Datasheet

1 NCP360 USB Positive Overvoltage Protection Controller
ON Semiconductor
2 NCP361 USB Positive Overvoltage Protection Controller
ON Semiconductor
3 NCP362 USB Positive Overvoltage and Overcurrent Protection
ON Semiconductor





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components