TL062A - Low-Power JFET-Input Operational Amplifiers

Download the TL062A datasheet PDF. This datasheet also covers the TL061 variant, as both devices belong to the same low-power jfet-input operational amplifiers family and are provided as variant models within a single manufacturer datasheet.

General Description

The TL06x (TL061, TL062, and TL064) family of industry-standard operational amplifiers (op amps) mirror the TL07x and TL08x family of op amps with lower power consumption.

Key Features

  • Very low power consumption.
  • Typical supply current: 200 μA (per amplifier).
  • Wide common-mode and differential voltage ranges.
  • Low input bias and offset currents.
  • Common-mode input voltage range includes VCC+.
  • Output short-circuit protection.
  • High input impedance: JFET-input stage.
  • Internal frequency compensation.
  • Latch-up-free operation.
  • High slew rate: 3.5 V/μs typical.
  • On products compliant to M.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (TL061-etcTI.pdf) that lists specifications for multiple related part numbers.

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
TL061, TL061A, TL061B, TL062, TL062A, TL062B, TL064, TL064A, TL064B SLOS078M – NOVEMBER 1978 – REVISED JUNE 2023 TL06xx Low-Power JFET-Input Operational Amplifiers 1 Features • Very low power consumption • Typical supply current: 200 μA (per amplifier) • Wide common-mode and differential voltage ranges • Low input bias and offset currents • Common-mode input voltage range includes VCC+ • Output short-circuit protection • High input impedance: JFET-input stage • Internal frequency compensation • Latch-up-free operation • High slew rate: 3.5 V/μs typical • On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.