Datasheet4U Logo Datasheet4U.com

LTC1000-SF - Current Transducer

Datasheet Summary

Features

  • Closed loop (compensated) current transducer using the Hall effect.
  • Insulating plastic case recognized IP IS RM according to UL 94-V0. UC Advantages UC.
  • Excellent accuracy.
  • Very good linearity.
  • Low temperature drift.
  • Optimized response time.
  • Wide frequency bandwidth.
  • No insertion losses.
  • High immunity to external interference.
  • Current overload capability.

📥 Download Datasheet

Datasheet preview – LTC1000-SF

Datasheet Details

Part number LTC1000-SF
Manufacturer LEM
File Size 509.57 KB
Description Current Transducer
Datasheet download datasheet LTC1000-SF Datasheet
Additional preview pages of the LTC1000-SF datasheet.
Other Datasheets by LEM

Full PDF Text Transcription

Click to expand full text
Current Transducer LTC 1000-SF For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. IP N = 1000 A Electrical data IP N Primary nominal RMS current IP M Primary current, measuring range @ ±24 V ÎP max Primary withstand peak current (maximum) RM Measuring resistance with ±15 V @ ±1000 A max @ ±1200 A max with ±24 V @ ±1000 A max @ ±2000 A max IS N Secondary nominal RMS current NP/NS Turns ratio UC Supply voltage (±5 %) IC Current consumption Accuracy - Dynamic performance data 1000 A 0 ... ±2400 1) A 10/10 kA/ms RM min 0 R dCl M max 15 dCp Ω 0 7 Ω 0 50 Ω 0 7 Ω 200 mA 1 : 5000 ±15 ...
Published: |