LinkCom Manufacturing Co.,Ltd LTC0508-50R HomePlug Transformer RoHS Compliant Operating Temperature -40°C to +85°C 2MHz to 30MHz bandwidth Electrical Specifications @25℃ Inductance PIN 8-5 = 10 uH Min. @ 2 MHz/0.1 V/Series PIN 1-4 = 10 uH Min. @ 2MHz/0.1 V/Series Leakage Inductance PN 8-5 = 90 nH Max. @ 2MHz/0.1 V (PIN 1,4 shorted) Turn Ratio PIN 8-5 : PIN 1-4 = 1±2% :1 Hi-POT. Pri.-Sec. = 3750 VAC/1 Second/1 mA Dimensions (Units: Inches mm , Unless otherwise specified, all toler.