Description
Metal cap with integrated IR window TO-46 (3 isolated + 1 ground) pins with solderable gold coating Si-based interference IR longpass filter Thermistor 100 kΩ The sensor is sealed in a dry nitrogen environment and gross leak proof PerkinElmer Logo “P” + device number xxxx + 3 digits date code YWW
2.2 Electrical Characteristics
Table 3: Thermopile sensor characteristics
Symbol RTP
Parameter Sensitive area Resistance
Min Typ 0.2
80
SV Responsivity
42
∆U / ∆T
∆U / ∆T τ VRMS
Average sensiti
Features
- Miniature TO-46 housing (4.7 mm Ø).
- Small and perfectly round measurement
spot.
- Large output voltage.
- Large field of view of 115°.
- High signal to noise ratio.
- 5.5 µm IR longpass filter.
- Stable signal in the case of ambient thermal
shock due to the small TO-46 housing.
- RoHS compliant.
- Si-chip made by
standard CMOS processes.