Description
G Green compound AEC-Q101 qualified
AVERAGE FORWARD CURRENT (A)
FIG.1 FORWARD CURRENT DERATING CURVE 30
25
20
15
10
5
0 50
RESISTIVE OR INDUCTIVE LOAD WITH HEATSINK
60 70 80 90 100 110 120 130 140 150 CASE TEMPERATURE (oC)
PEAK FORWARD SURGE CURRENT (A)
FIG.2 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER LEG
250 8.3ms Single Half Sine-Wave
225 JEDEC Method
200
175
150
125
100 1
10 NUMBER OF CYCLES AT 60 Hz
100
FIG.3 TYPICAL FORWARD CHARACTERSTICS PER LEG
100
FIG.4 TYPICA
Features
- - Low power loss, high efficiency - Ideal for automated placement - Guardring for overvoltage protection - High surge current capability - Moisture sensitivity level: level 1, per J-STD-020
- Compliant to RoHS Directive 2011/65/EU and in accordance to WEEE 2002/96/EC
- Halogen-free according to IEC 61249-2-21 definition.