LPE-6562-A262, Power Transformer
LPE-6562-A262 Vishay Dale Power Transformer DIMENSIONS in inches [millimeters] ELECTRICAL SPECIFICATIONS Primary Inductance (3, 4, 5 - 2,1): 12.8µH ± 20% @ 0.1Vrms, 100KHz Primary DC Current Continuous (3, 4, 5 - 2, 1): 3.0A(dc) for temperature rise of 30°C maximum Primary Incremental Current (or Peak Current): 3.28A(dc) typical for less than 20% reduction of inductance Primary DC Resistance (3, 4, 5 - 2, 1): 0.031 ohm maximum on combined windings Secondary DC Resistance (7 - 10): 0.17 ohm ma