TCM1060 - DUAL TRANSIENT-VOLTAGE SUPPRESSORS
The TCM1030 and TCM1060 dual transient-voltage suppressors are designed specifically for telephone line card protection against lightning and transients induced by ac lines. One of the TIP terminals (pin 1 or 8) and one of the RING terminals (pin 4 or 5) are connected to the tip and ring circuits of.
TCM1030, TCM1060 DUAL TRANSIENT-VOLTAGE SUPPRESSORS Meets or Exceeds Bell Standard LSSGR Requirements Externally Controlled Negative Firing Voltage . . . 70 V Max Wide, Accurately Controlled, Negative Firing Voltage Range . . . 5 V to 65 V Surge Current (see Note 1) TCM1030 10/1000 16 A 10/160 25 A 2/10 35 A TCM1060 30 A 45 A 50 A High Holding Current TCM1030 . . . 100 mA Min TCM1060 . . . 150 mA Min .