S-8240A Overview
Key Specifications
Operating Voltage: 1.8 V
Max Voltage (typical range): 6 V
Min Voltage (typical range): 1.5 V
Length: 1.2 mm
Key Features
- 0.200 V to -0.015 V (5 mV step) Accuracy ±5 mV
- Detection delay times are generated only by an internal circuit (external capacitors are unnecessary)
- 0 V battery charge: Enabled, inhibited
- Power-down function: Available, unavailable
- Release condition of discharge overcurrent status: Load disconnection, charger connection
- Release voltage of discharge overcurrent status: VRIOV, VDIOV
- High-withstand voltage: VM pin and CO pin: Absolute maximum rating 28 V
- Wide operation temperature range: Ta = -40°C to +85°C
- Lead-free (Sn 100%), halogen-free *1. Overcharge release voltage = Overcharge detection voltage
- Overcharge hysteresis voltage (Overcharge hysteresis voltage can be selected from a range of 0 V to 0.4 V in 50 mV step.) *2. O