Datasheet4U Logo Datasheet4U.com

A1302 - Continuous-Time Ratiometric Linear Hall Effect Sensor

Download the A1302 datasheet PDF. This datasheet also covers the A1301 variant, as both devices belong to the same continuous-time ratiometric linear hall effect sensor family and are provided as variant models within a single manufacturer datasheet.

General Description

The A1301 and A1302 are continuous-time, ratiometric, linear Hall-effect sensor ICs.

They are optimized to accurately provide a voltage output that is proportional to an applied magnetic field.

These devices have a quiescent output voltage that is 50% of the supply voltage.

Key Features

  • Low-noise output.
  • Fast power-on time.
  • Ratiometric rail-to-rail output.
  • 4.5 to 6.0 V operation.
  • Solid-state reliability.
  • Factory-programmed at end-of-line for optimum performance.
  • Robust ESD performance Packages: 3-Pin SOT23W (suffix LH) 3-Pin SIP (suffix UA) Not to scale.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (A1301_AllegroMicroSystems.pdf) that lists specifications for multiple related part numbers.

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
A1301 and A1302 Continuous-Time Ratiometric Linear Hall-Effect Sensor ICs FEATURES AND BENEFITS • Low-noise output • Fast power-on time • Ratiometric rail-to-rail output • 4.5 to 6.0 V operation • Solid-state reliability • Factory-programmed at end-of-line for optimum performance • Robust ESD performance Packages: 3-Pin SOT23W (suffix LH) 3-Pin SIP (suffix UA) Not to scale DESCRIPTION The A1301 and A1302 are continuous-time, ratiometric, linear Hall-effect sensor ICs. They are optimized to accurately provide a voltage output that is proportional to an applied magnetic field. These devices have a quiescent output voltage that is 50% of the supply voltage. Two output sensitivity options are provided: 2.5 mV/G typical for the A1301, and 1.3 mV/G typical for the A1302.