Datasheet4U Logo Datasheet4U.com

DG502 - STAND-ALONE PROXIMITY

Features

  • Input voltage Output Anti-triggering contact Badge entry Master code Inputs Keyboard Distance between the auxiliary reader and the main reader 12V ~ or = 2 relays, N/O & N/C contact 3 amp @ 125V 500 milli amp 50V ~ or = 500 programmable badges 5-digit programmable code 2 request-to-exit 12-digit keypad with built-in buzzer (audible signal) minimum 60 cm, maximum 50 m (cable minimum 7 x 0.6 mm2) Warning: Do not use a switching power supply because of the interference radiation that may disturb t.

📥 Download Datasheet

Datasheet preview – DG502

Datasheet Details

Part number DG502
Manufacturer CDVI
File Size 390.56 KB
Description STAND-ALONE PROXIMITY
Datasheet download datasheet DG502 Datasheet
Additional preview pages of the DG502 datasheet.
Other Datasheets by CDVI

Full PDF Text Transcription

Click to expand full text
Edition 02/2000 DG502 Y2K STAND-ALONE PROXIMITY SYSTEM 500 PROXIMITY BADGES 2 DOORS Wiring diagram WIRING DIAGRAM AND INSTRUCTIONS PCB front view 1 4 2 5 8 0 3 6 9 Warning Do not use a switching power supply because of the interference radiation that may disturb the reading of the badges 12 3 7 … ST1 # RL1 RL2 R C T R C T S S B M E 1 2 3 4 5 6 12 V 12 V Strike M A G N E T PB1 PB2 V1 V2 230V~ Input voltage 12V ~ or = B E M R C T V1 V2 ST1 S, S RL1 RL2 Push button 1 Push button 2 Common PB1 PB2 N/C contact Common N/O contact Varistor RL1 Varistor RL2 Reset jumper Trigger output Door 1 relay output Door 2 relay output Auxiliary reader (terminal connections) See wiring diagram of auxiliary readers 12 V 1 2 3 4 5 Input voltage Input voltage Data Buzzer Green LED Common Red