LPT25
LPT25 is AC-DC / 10W - 85W manufactured by Emerson.
- Part of the LPT25_lpt20series_ds_1184686751_ds comparator family.
- Part of the LPT25_lpt20series_ds_1184686751_ds comparator family.
Features
- -
- -
- -
- -
- -
- -
- Universal input 3" x 5" footprint Less than 1U high Remote sense on main output Terminal block option (-T) Built-in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available 2 year warranty
Input
Input range Frequency Inrush current Input current Efficiency EMI 85-264 VAC 120-300 VDC 47-440 Hz <15A peak @ 115VAC; <30A peak @ 230VAC, cold start @ 25°C 1 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 m A @ 50/60 Hz, 264 VAC input
Safety ground leakage current
Output
Maximum Power Cross regulation Adjustment range Hold-up time Overload protection Overvoltage protection Remote sense 25W for convection; 40W with 30CFW forced air ±2% on output 1; ±5% on outputs 2, 3 -5, +10% minimum 20 ms @ 25 W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating 5.7 to 6.7 VDC on the main output pensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Safety
VDE 0805 EN60950 11774-3336-1241 (LC#84936) UL UL60950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P95100411 (74-sec) 203 CB Certificate and report 1569, 1570, 1571, 1572 CE Mark (LVD)
Embedded Power for Business-Critical Continuity
Environmental Specifications
Operating temperature: Electromagnetic susceptibility: Humidity: Vibration: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C, -20°C start up. Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational -40° to 85°C ±.04% per °C >550,000 hours at full load and 25°C ambient conditions
Rev. 02.05.07 LPT25 Series 2 of...