MAXIMUM RATINGS
& Recommended Operating Conditions Parameter, unit Symbol Recommended operating conditions min max Supply voltage, V UCC 3,0 3,6 Input voltage (digital inputs), V Low level input voltage (digital inputs), V High level input voltage (digital inputs), V Transmitter output voltage, V Receiver input voltage, V Voltage applied to receiver output , V Ambient temperature, oC UI UIL UIH UOD UIR URO TA - 0 2,0 – 7,0 – 7,0 0 -40 - 0,8 Ucc 12,0 12,0 Ucc 85 ILX3485 Maximum rate min max - 7,0 -0,3 7,0 -- –-7,5 12,5 -7,5 12,5 -0,3 Ucc+0,3 -60 150 Electric parameters Parameter, unit Symbol Low level input leakage current, uA High level input leakage current, uA Idle mode supply current, uA IILL IILH IСС Low power consumption mode supply current, uA Time of transition to Low power consumption mode Receiver Low level output voltage, V High level output voltage, V Input current, mA ISHDN tSHDN UOL UOH IIN2 Low level output current for state “Off”, uA High level output current for state “...