Datasheet4U Logo Datasheet4U.com

HTFS400-P-SP7 Datasheet Current Transducer

Manufacturer: LEM

Overview

Current Transducer HTFS 400-P/SP7 For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

IP N = 400 A Electrical data All data are given with RL = 10 kΩ IP N Primary nominal RMS current IP M Primary current, measuring range Uout Output voltage (Analog) @ IP IP = 0 Uref Reference voltage Uref Output voltage 1) Uref Output impedance Uref Load impedance RL Load resistance Rout Output internal resistance CL Load capacitance UC Supply voltage (±5 %) IC Current consumption @ UC = 3.3 V 400 A ±600 A Uref ±(0.77 × IP/IP N) V Uref ±0.025 V 1.65 ±0.025 V 200 (typ) Ω ≥ 200 kΩ ≥ 2 kΩ < 5 Ω 4.7 nF 3.3 V Typ Max 19 25 mA Accuracy - Dynamic performance data ε εL TCUO E TCUref TCS UO M Uno tD 10 tD 90 BW Error 2) @ IP N, TA = 25 °C Linearity error 0 ...

1.5 × IP N Temperature coefficient of UO E @ IP = 0 Temperature coefficient of Uref Temperature coefficient of S Magnetic offset voltage @ IP = 0 and specified RM, after an overload of 3 × IP N DC RMS noise voltage referred to primary (DC ...

Key Features

  • Hall effect measuring principle.
  • Galvanic separation between primary and secondary circuit.
  • Low power consumption.
  • Insulating plastic case recognized according to UL 94-V0.
  • TA =.
  • 40 °C +105 °C. Special features.
  • Single power supply +3.3 V.
  • PCB fixation with 4 pins ⌀ 1 mm.
  • Fixed offset. Advantages.
  • Small size and space saving.
  • Only one design for wide current ratings range.
  • High.