  • Triggering, status, and control are provided to support the proper functioning of the channel. A STIM contains the TEDS, logic to implement the transducer interface, the transducer(s) and any signal conversion or signal conditioning. A STIM is controlled by a NCAP module by means of a dedicated digital interface. This interfac.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
AN214 The PICmicro® MCU as an IEEE 1451.2 Compatible Smart Transducer Interface Module (STIM) Authors: Richard L. Fischer Microchip Technology Inc. Jeff Burch Agilent Technologies The IEEE 1451.2 standard provides the means to connect sensors and actuators to a digital system, typically a network, via a Network Capable Application Processor (NCAP). Figure 2 depicts a general distributed measurement and control application and Figure 3 depicts the functional boundaries relating to the transducer interface standard, namely IEEE 1451.2. In simplest terms, the IEEE-1451.2 standard does the following: • Defines a digital interface for connecting transducers to microprocessors. • Describes a TEDS, “electronic data sheet”, and its data formats.