NE1118 - PWM controller

General Description

Pro 1 FB 2 , CS 3 GND 4 GATE 5 VCC 6 NC 7 HV 8 X Cap NEM Confidential 4 PSU Specifications Input Characteristics Rated Input Voltage: 90~264Vac Frequency Range: 47~63Hz: Efficiency: Eff.> 87.4% @115V/230Vac, Po=36W BI/Bo:85Vac/75Vac;BO Delay time:

Key Features

  • to enhance the performance of off-line power supply in SOP-8 package. With the adjustable OPP function integrated in HV pin, it is easy to design the over power protection well under high/low line condition.
  • Turbo boost technology during over load or peak load condition Power boost in a specific period.
  • HV startup with low leakage current, Brown out function. Increased frequency during peak load operation to avoid.
  • Safety Protection: Vcc-GND short test, LPS limita.

📥 Download Datasheet

Datasheet Details

Part number NE1118
Manufacturer NEM
File Size 1.20 MB
Description PWM controller
Datasheet download datasheet NE1118 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
NE1118 12V/3A COC V5.0 Tier2 &DOE V6.0 Design NEM Confidential The NE1118 is a highly integrated PWM controller. It is built-in with several features to enhance the performance of off-line power supply in SOP-8 package. With the adjustable OPP function integrated in HV pin, it is easy to design the over power protection well under high/low line condition • Turbo boost technology during over load or peak load condition Power boost in a specific period • HV startup with low leakage current, Brown out function. Increased frequency during peak load operation to avoid • Safety Protection: Vcc-GND short test, LPS limitation. transformer saturation.