Datasheet4U Logo Datasheet4U.com

NSi1306 - Isolated Sigma-Delta Modulator

General Description

6.1.

INSULATION AND SAFETY RELATED SPECIFICATIONS 14 6.2.

INSULATION CHARACTERISTICS 14 6.3.

Key Features

  • Up to 5000VRMS Insulation Voltage.
  • Clock frequency: 5MHz to 21MHz.
  • ±50mV or ±250mV Linear Input Voltage Range.
  • Excellent DC Performance:.
  • Offset Error: ±50μV or ±100μV (Max).
  • Offset Drift: -0.5~1.5μV/℃ (Max).
  • Gain Error: ±0.2% (Max).
  • Gain Drift: ±40ppm/℃ (Max).
  • SNR: 82.5dB or 86dB (Typ).
  • High CMTI: 150kV/μs (Typ).
  • System-Level Diagnostic Features:.
  • AVDD monitoring.
  • Input common-mode overvoltage detection.
  • Operation Temperatu.

📥 Download Datasheet

Datasheet Details

Part number NSi1306
Manufacturer NOVOSENSE
File Size 1.50 MB
Description Isolated Sigma-Delta Modulator
Datasheet download datasheet NSi1306 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
NSi1306 High Reliability Reinforced Isolated Sigma-Delta Modulator Datasheet (EN) 1.6 Product Overview The NSI1306 is a high performance Σ-Δ modulator with output separated from input based on the NOVOSENSE capacitive isolation technology. The device has a linear differential input signal range of ±50mV (±64mV full-scale) or ±250mV (±320mV full-scale). The differential input is ideally suited to shunt resistor-based current sensing in high voltage applications where isolation is required. The analog input is amplified and continuously sampled by a second-order Σ-Δ modulator and converted to a high speed, single bit data stream. The output data is synchronous to the external clock with a frequency range from 5MHz to 21MHz.