Description
The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments Ground fault currents greater than a presettable threshold value will trigger an external SCR-driven circuit breaker to interrupt the AC line and remove the fault condition In addit
Features
- include circuitry that rapidly resets the timing capacitor in the event that noise pulses introduce unwanted charging currents and a memory circuit that allows firing of even a sluggish breaker on either half-cycle of the line voltage when external full-wave rectification is used
Features
Y Y Y Y Y
Y
Internal power supply shunt regulator Externally programmable fault current threshold Externally programmable fault current integration time Direct interface to SCR Operates under line reversal b.