Unisonic Technologies LM1851
LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments. 7 TIMING CAP -IN +IN RSET GND 2 3 100k 0.047μF 1 SCR TRIGGER 5 A Ct 0.002 Iss 8 OP AMP OUTPUT Vcc 1.5M 800Hz 6 4 + - 300mV 1k 31V FIGURE 1.Normal Fault Sensitivity Test Circuit CIRCUIT DESCRIPTION (Refer to Block and Connection Diagram) The UTC LM1851 operates from 26V as set by an internal shunt...DESCRIPTION
The UTC Ground fault currents greater than a presentable threshold value will trigger an external SCR-driven circuit breaker to interrupt the AC line and remove the fault condition. In addition to detection of conventional hot wire to ground faults, the neutral fault condition is also detected. Full advantage of the U.S. UL943 timing specification is taken to insure maximum immunity to false triggering due to line noise. Special features include circuitry that rapidly resets the timing capacitor in the event that noise pulses introduce unwanted charging currents and a memory circuit that allows firing of even a sluggish breaker on either half-cycle of the line voltage when external full-wave rectification is used. DIP-8 SOP-8FEATURES
* Internal power supply shunt regulator * Externally programmable fault current threshold * Externally programmable fault current integration time * Direct interface to SCR * Operates under line reversal; both load vs line and hot vs neutral *...