Picker PCS24
the PCS24 relay with an inductive load, it is suggested to select Random Turn-On. The maximum transient voltage value listed in this datasheet is the non-repetitive peak value. The PCS24 is not suitable for capacitive loads; if you must switch a capacitive load, do not choose the varistor protection option.FEATURES
● SCR Output (530V version), Triac Output (440V version)● LED Status Indicator
● Built-In Snubber
● Removable Finger Safe Cover Option OUTPUT CURRENT PARAMETERS (Ta = 30°C) Load Current (200mA min)** 10A 15A 25A 40A 50A 60A Max I2t (10 ms, A2s) 50 112 312 800 1250 1800 Max Surge Current (10 ms, Apk) 100 150 250 400 500 600 Thermal Resistance Junction to Case (Rjc, °C/W) 2.35 2.15 1.15 1.15 0.63 0.63 **Minimum current loading over range required to fully turn-on device. Standard UL endurance ratings are 6,000 cycles OUTPUT VOLTAGE PARAMETERS 380A Load Voltage Range (VAC) 48~440 Max Transient Voltage (Vpk) 800 Max Off-State Leakage Current 10 mA Max On-State Voltage Drop 1.7 Vrms Max Turn-On Time Zero Cross 1/2 cycle + 1ms Random 1ms Max Turn-Off Time 1/2 cycle + 1ms Min Off-State (dv/dt) 200 V/us Min Power Factor 0.5 Frequency Range 47 Hz to 63 Hz 480A 48~530 1200 CHARACTERISTICS Insulation Resistance 1000 MΩ at 500 VDC Dielectric Strength 4000 VAC, 50/60 Hz, 1 min, Input to O...