Picker PCS28
the PCS28 relay with an inductive load, it is suggested to select Random Turn-On. The PCS28 is not suitable for capacitive loads; if you must, then do not choose products with varistor protection.FEATURES
E93379● Two Independently Controlled Relays
● SCR Output
● Screw Terminal Available
● Built In Snubber
● Optical Isolation between Input & Output OUTPUT CURRENT PARAMETERS (Ta = 30°C) Load Current (100mA min)** 25A 40A Max Surge Current (10 ms, Apk) 300 400 Max I2t (10 ms, A2s) 450 800 Thermal Resistance Junction to Case (Rjc, °C/W) 1.15 0.25 **Minimum current loading over range required to fully turn on device. Standard UL endurance ratings are 6,000 cycles. 50A 500 1250 0.20 OUTPUT VOLTAGE PARAMETERS Load Voltage 240A 380A Load Voltage Range (VAC) 48~280 48~440 Max Transient Voltage (Vpk) 600 800 Max Turn-On Time Random 1 ms Zero Crossing 1/2 cycle + 1 ms Max Off-State Leakage Current 10 mA Max On-State Voltage Drop 1.5 Vrms Min Power Factor 0.5 Max Turn-Off Time 1/2 cycle + 1 ms Frequency Range 47 Hz to 63 Hz Min Off-State (dv/dt) 500 V/us 480A 48~530 1200 CHARACTERISTICS Dielectric Strength 2500 VAC, 50Hz/60Hz, 1 min Input, Output to Output 4000 VAC, 50Hz/60Hz, 1 min Inpu...