ESOT24LCC-2
ESOT24LCC-2 is LOW CAPACITANCE TVS ARRAY manufactured by Protek Devices.
Only One Name Means Pro T ek’Tion™
LOW CAPACIT ANCE TVS ARRA Y
APPLICA TIONS ✔ Ethernet
- 10/100/1000 Base T ✔ CAN Bus ✔ Cellular Phones ✔ Audio/Video Inputs ✔ Personal Digital Assistant (PDA) ✔ E1/T1 & E3/T3 IEC PA TIBILITY (EN61000-4) ✔ 61000-4-2 (ESD): Air
- 15k V, Contact
- 8k V ✔ 61000-4-4 (EFT): 40A
- 5/50ns FEA TURES ✔ ESD Protection > 25 kilovolts ✔ 100 Watts Peak Pulse Power per Line (tp = 8/20µs) ✔ Protects Two (2) Bidirectional Lines ✔ Bidirectional Configuration ✔ Low Leakage Current < 1.0µA ✔ LOW CAPACITANCE: 6p F PER LINE ✔ Ro HS pliant on Lead-Free Versions MECHANICAL CHARACTERISTICS ✔ ✔ ✔ ✔ Molded JEDEC SOT-23 Weight 8 milligrams (Approximate) Available in Tin-Lead or Lead-Free Pure-Tin Plating(Annealed) Solder Reflow Temperature: Tin-Lead
- Sn/Pb, 85/15: 240-245°C Pure-Tin
- Sn, 100: 260-270°C ✔ Flammability rating UL 94V-0 ✔ 8mm Tape and Reel Per EIA Standard 481 ✔ Device Marking: Marking Code
SOT-23
PIN CONFIGURA TION
1 3 2
05194.R1 3/05
.protekdevices.
DEVICE CHARACTERISTICS MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PARAMETER Peak Pulse Power (tp = 8/20µs)
- See Figure 1 Peak Pulse Current (tp = 8/20µs) Operating Temperature Storage Temperature SYMBOL PPP IPP TJ TSTG VALUE 100 2 -55°C to 150°C -55°C to 150°C UNITS Watts A °C °C
ELECTRICAL CHARACTERISTICS PER LINE @ 25°C Unless Otherwise Specified
PART NUMBER (See Note 1 & 2) DEVICE MARKING CODE RATED STAND-OFF VOLTAGE MINIMUM BREAKDOWN VOLTAGE MAXIMUM LEAKAGE CURRENT TYPICAL CAPACITANCE PER LINE
VWM VOLTS ESOT24LCC-2 24L 24.0
@ 1m A V(BR) VOLTS 26.6
@VWM ID µA 1
@0V, 1MHz C p F 6
Note 1: Test between pins 1 to 3 and 2 to 3 in both directions. Note 2: Per IEC 61000-4-2, ESD ± 25k V.
FIGURE 1 PEAK PULSE POWER VS PULSE TIME
10,000
- Peak Pulse Current
- % of IPP PPP
- Peak Pulse Current
- Watts
120 100 80 60 40 20 0 tf
FIGURE 2 PULSE WAVE FORM
Peak Value IPP TEST WAVEFORM PARAMETERS tf = 8µs td = 20µs
1,000 e-t
100W, 8/20µs Waveform 100 td =...