100VAC Input/12VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5037B12
Absolute Maximum Ratings
Parameter Input voltage Maximum Output current ESD endurance Operating temperature range Storage temperature range Maximum surface temperature Symbol Vi Iomax Vsurge Topr Tstg Tcmax Limits 170 200 2 −25 to +80 −25 to +105 105 Unit V mApk kV °C °C °C
16.8MAX.
Dimensions (Unit : mm)
28.2MAX. 9.0MAX. Mark Side 1 3 5 0 . 5 ±0 . 1 (2.54�9=)22.86 TYP. 7 7.62 1 . 3 ±0 . 2 10 0 . 2 5 ±0 . 0 5 5.05MAX. 3.95MAX. 5.08 3.3MAX
Electrical Characteristics
Symbol Min. Parameter Input voltage range 113 Vi Output voltage 11.0 Vo Output current 0 Io Line regulation − Vr Load regulation − Vl Output ripple voltage − Vp Power conversion efficiency 70 η Typ. 141 12.0 − 0.05 0.07 0.05 78 Max. 170 13.