Datasheet4U Logo Datasheet4U.com

BP5061 - Non-Isolated AC/DC Converter

📥 Download Datasheet

Datasheet preview – BP5061

Datasheet Details

Part number BP5061
Manufacturer ROHM
File Size 538.55 KB
Description Non-Isolated AC/DC Converter
Datasheet download datasheet BP5061 Datasheet
Additional preview pages of the BP5061 datasheet.
Other Datasheets by Rohm

Full PDF Text Transcription

Click to expand full text
Data Sheet 100VAC Input/−12VDC (300mA) Output Non-Isolated AC/DC Converter BP5061 Absolute Maximum Ratings Parameter Input voltage Output current ESD endurance Operating temperature range Storage temperature range Symbol Vi Io Vsurge Topr Tstg Limits −170 300 2 −25 to +80 −25 to +105 Unit V mApk kV °C °C Electrical Characteristics Parameter Symbol Min. Input voltage range Output voltage Output current Vi −113 Vo −11.0 Io 0 Line regulation Load regulation Output ripple voltage Power conversion efficiency Vr Vl Vp η − − − 70 Typ. −141 −12.0 − 0.04 0.05 0.07 78 Max. −170 −13.0 300 0.15 0.15 0.
Published: |