Data Sheet
100VAC Input/−24VDC (600mA) Output
Non-Isolated AC/DC Converter
BP5068A24
Absolute Maximum Ratings
Parameter Input voltage Output current ESD endurance Operating temperature range Storage temperature range
Symbol Vi Io
Vsurge Topr Tstg
Limits −190 0.8
2 −20 to +80 −25 to +105
Unit V
Apk kV °C °C
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range Output voltage Output current Line regulation Load regulation Output ripple voltage Power conversion efficiency
Vi Vo Io Vr Vl Vp
η
−162 −26.0
0
−
−
− 82
−141 −24.0
− 0.23 0.55 0.11 88
−120 −22.0
0.6 0.48 0.75 0.