Data Sheet
100VAC Input/−5V (500mA) Output
Non-Isolated AC/DC Converter
BP5062A5
Absolute Maximum Ratings
Parameter Input voltage Output current ESD endurance Operating temperature range Storage temperature range
Symbol Vi Io
Vsurge Topr Tstg
Limits −195 500
2 −20 to +80 −25 to +105
Unit V
mApk kV °C °C
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi −113 −141 −195 V DC (80 to 137VAC)
Output voltage
Vo −4.7 −5.0 −5.3 V Vi=−141V, Io=500mA
Output current
Io 0 − 500 mA Vi=−141V
∗1
Line regulation
Vr
− 0.05 0.2
V Vi=−113V to −195V, Io=500mA
Load regulation
Vl
− 0.07 0.3
V Vi=−141V, Io=0 to 500mA
Output ripple voltage Vp
− 0.15 0.