BP5075-12
BP5075-12 is Non-Isolated AC/DC Converter manufactured by ROHM.
Data Sheet
110VAC Input/- 12VDC (100m A) Output
Non-Isolated AC/DC Converter
Absolute Maximum Ratings
Parameter Input voltage Operating temperature range Storage temperature range Case temperature Output current Symbol Vi Topr Tstg Tsmax Iopeak Limits
- 187
- 20 to +80
- 25 to +105 105 100 Unit V °C °C °C m Apk
19.5MAX.
Dimensions (Unit : mm)
20.5MAX. 10.7MAX.
MARKING SIDE
4.0±1.0
0.5±0.1
4 5 6 7
P=2.54±0.2 1.3±0.2 4.45MAX. 0.25±0.05 6.25MAX.
Electrical Characteristics
Symbol Min. Parameter Input voltage
- 113 Vi Output voltage
- 11.7 Vo Output current
- Io Line regulation
- Vr Load regulation
- Vl Output ripple voltage
- Vp Conversion efficiency 68 η Typ.
- 141
- 12.5
- 0.02 0.01 0.04 73 Max.
- 187
- 13.2 100 0.20 0.20 0.20
- Unit V V m A V V Vp-p % Conditions DC Vi=- 141V, Io=50m A
∗1
3.25MAX.
2.54x6=15.24TYP.
Derating Curve
120 Output Current Io(m A) 100 80 60 40 20 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature Ta(°C) Operation Range
Vi=- 113 to
- 187V Vi=- 141V, Io=0 to 50m A Vi=- 141V, Io=50m A ∗2 Vi=- 141V, Io=100m A
∗1 Max output current should be reduced according to the surrounding temperature. ∗2 The output ripple voltage may vary depending on the capacitance, environment, and location of peripheral ponents. Especially right attention has to be paid to aluminum electrolytic capacitor, because ESR changes greatly at the time of the low temperature and output ripple voltages increase.
Application...