BP5075-5
BP5075-5 is Non-Isolated AC/DC Converter manufactured by ROHM.
Data Sheet
220VAC Input/- 5VDC (120m A) Output
Non-Isolated AC/DC Converter
Absolute Maximum Ratings
Parameter Input voltage Operating temperature range Storage temperature range Maximum surface temperature Maximum output current Symbol Vi Topr Tstg Tsmax Iopeak Limits
- 170
- 20 to +80
- 25 to +105 105 120 Unit V °C °C °C m Apk
19.5MAX.
Dimensions (Unit : mm)
20.5MAX. 10.7MAX. Mark Side
4.0±1.0
0.5±0.1
4 5 6 7
P=2.54±0.2 1.3±0.2 2.54x6=15.24TYP. 4.45MAX. 0.25±0.05 6.25MAX.
3.25MAX.
Electrical Characteristics
Symbol Min. Parameter Input voltage
- 113 Vi Output voltage
- 4.7 Vo Output current
- Io Line regulation
- Vr Load regulation
- Vl Output ripple voltage
- Vp Power conversion efficiency 55 η Typ.
- 141
- 5.0
- 0.02 0.03 0.04 59 Max.
- 170
- 5.3 120 0.20 0.20 0.20
- Unit V V m A V V Vp-p % Conditions DC(80 to 120VAC) Vi=- 141V, Io=60m A
∗1
Output Current Io(m A)
Derating Curve
140 120 100 80 60 40 20 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature Ta(°C) Operation Range Derating Curve
Vi=- 113 to
- 170V, Io=60m A Vi=- 141V, Io=0 to 60m A ∗2 Vi=- 141V, Io=60m A Vi=- 141V, Io=120m A
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve. ∗2 The output ripple voltage may vary depending on the capacitance, environment, and location of peripheral ponents. Particular attention must be paid to aluminum electrolytic capacitor, because ESR changes greatly at the time of the low temperature and output ripple voltages increase.
Application Circuit
Be sure to use fuse for...