SN8P1704
Key Features
- Change “Four internal interrupts” to “Three internal interrupts” in SN8P1704 FEATURES section
- Change “ACC can’t be access by “B0MOV” instruction” to “ACC can’t be access by “B0MOV” instruction during the instant addressing mode”
- Correct the description of STKnH
- Change “special register is located at 08h~FFh” to “special register is located at 80h~FFh”
- Correct the bit definition of INTEN register
- Correct the description of “TC0 CLOCK FREQUENCY OUTPUT” section
- Correct the description of “TC1 CLOCK FREQUENCY OUTPUT” section
- SCKMD = 1 means SIO is in SLAVE mode. SCKMD = 0 means SIO is in MASTER mode
- Remove “SIO clock and SPI clock are compatible”
- Modify ADB’s output data table